60mm 60 60 56 mm inlet side , outlet side features counter rotating fan 60 counter rotating fan 60mm common speci?cations dimensions (unit : mm) reference dimension of mounting holes and vent opening (unit : mm) cra type | m 3 /min | cfm | pa | inchh 2 o | db(a) |? | h model no. rated voltage | v operating voltage range |v rated current | a rated input | w max. air flow max. static pressure spl operating temperature expected life note1) note2) pwm duty cycle |% note1 : pwm frequency : 25khz note2 : expected life at 40? ambient is just reference value. 12 10.8 to 13.2 20 to 70 40,000/60 ? (70,000/40 ? ) 30,000/60 ? 100 0 100 0 100 0 rated speed | min -1 i n l e t o u t l e t 3.10 0.17 2.30 0.15 1.30 0.10 9CRA0612P6K001 9cra0612p6j001 9cra0612p6g001 37.2 2.0 27.6 1.8 15.6 1.2 18,300 15,800 3,800 3,300 16,800 14,500 3,800 3,300 13,500 11,400 3,000 2,500 2 . 2 8 0 . 4 7 2 . 1 0 0 . 4 7 1 . 6 5 0 . 3 6 8 0 . 5 1 6 . 6 7 4 . 2 1 6 . 6 5 8 . 3 1 2 . 7 1 , 1 3 0 4 9 9 5 0 4 9 6 2 0 3 1 4 . 5 4 0 . 2 0 3 . 8 2 0 . 2 0 2 . 4 9 0 . 1 2 73 35 70 35 65 29 3-33-1, minami-otsuka, toshima-ku, tokyo, 170-8451, japan tel: +81 3 5927 1020 http://www.sanyodenki.com the names of companies and/or their products speci?ed in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. ?san ace? is a trademark of sanyo denki co.,ltd. speci?cations are subject to change without notice. 59 29.7 500.3 59 29.7 500.3 4-?4.5 speci?cations ? material kkkkkkkkkkkkkkkkkkkkkkkkkk ? expected life kkkkkkkkkkkkkkkkkkkkk ? motor protection system kkkkkkkkkk ? dielectric strength kkkkkkkkkkkkkkkk ? sound pressure level (spl) kkkkkkkk ? operating temperature kkkkkkkkkkkk ? storage temperature kkkkkkkkkkkkkk ? lead wire kkkkkkkkkkkkkkkkkkkkkkkk ? mass kkkkkkkkkkkkkkkkkkkkkkkkkkkkk frame, impeller : plastics (flammability: ul94v-0) varies for each model (l10: survival rate: 90% at 60?, rated voltage, and continuously run in a free air state) current blocking function and reverse polarity protection 50/60 hz, 500vac, 1 minute (between lead conductor and frame) expressed as the value at 1m from air inlet side varies for each model (non-condensing) 30 ? to 70 ? (non-condensing) i n l e t : redy ? blackysensor: yellow control: brown o u t l e t : orangey ? grayysensor: purple control: white approx. 200g ? the products shown in the catalog are subject to japanese export control law. diversion contrary to the law of exporting country is prohibited. ? to protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. notice catalog no. c1023b001 ?13.9 high air flow and high static pressure even with a thickness 20 mm less, the maximum air flow of this fan is approximately 1.1 times and its maximum static pressure is approximately 1.1 times greater than that of our conventional counter rotating fan. * this contributes to space optimization in devices. * : specification of model no. 9CRA0612P6K001. our conventional counter rotating fan is 60 x 60 x 76 mm ? san ace 60 ? cra type, model no. 9cra0612p0g001. air flow direction rotating direction rotating direction l e a d w i r e mounting hole a wg26 ul1430 inlet side outlet side 62.7 62.7 mounting hole 56 ? 0.5 (4) (4) 4-?4.5 ? 0.3 +50 30 0 0 (1 0) 60 ? 0.5 50 ? 0.3 60 ? 0.5 50 ? 0.3 4-?4.5 ? 0.3
pwm input signal example example of connection schematic speci?cations for pulse sensors output circuit : open collector t 1 ? 4 1/4 t 0 t 1 ? 4 1/4 t 0 1 60/4n sec n 1 fan speed min -1 one revolution in case of steady running output waveform need pull-up resistor inside of dc fan sensor output sensor pull-up resistor pull-up voltage input signal waveform t 100 t1 t 1 v ih =4.75v to 5.25v v il =0v to 0.4v pwm duty cycle % = pwm frequency 25 khz = source current : 5ma max. at control voltage 0v sink current : 5ma max. at control voltage 5.25v control terminal voltage : 5.25v max. (open circuit) when the control lead wire is open, the fan speed is the same as the one at a pwm duty cycle of 100%. either ttl input, open collector or open drain can be used for pwm control inpu t signal. pwm input signal dc fan input voltage control inside of dc fan isource isink v ce 1 13.8v max. ic 1 10ma max. | v ol 1 v ce sat 1 1.0v max. t t 1 v il t 0 t 1 0v v ol v oh t 2 t 3 t 4 v ih ic v ce pwm duty - speed characteristics example air flow - static pressure characteristics pwm duty cycle % speed min -1 voltage dc12v pwm frequency 25khz pwm duty cycle % speed min -1 pwm duty cycle % speed min -1 voltage dc12v pwm frequency 25khz voltage dc12v pwm frequency 25khz 9CRA0612P6K001 9cra0612p6g001 9cra0612p6j001 11,400 min -1 13,500 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 14,500 min -1 16,800 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 inlet side outlet side inlet side outlet side inlet side outlet side 15,800 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 20,000 18,300 min -1 ~ pwm duty cycle ~ operating voltage range static pressure air ?ow static pressure static pressure static pressure air ?ow static pressure air ?ow static pressure air ?ow air ?ow air ?ow pwm duty cycle 100 ? pwm duty cycle 100 ? pwm duty cycle 100 ? dc 12v dc12v pa inch h 2 o 9cra0612p6j001 pa inch h 2 o 9cra0612p6j001 cfm m 3 /min cfm m 3 /min pa inch h 2 o 9cra0612p6g001 pa inch h 2 o 9cra0612p6g001 cfm m 3 /min cfm m 3 /min 9CRA0612P6K001 9CRA0612P6K001 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 pwm duty cycle 100% 50% 0% 50% 0% 13.2v 12v 10.8v 13.2v 12v 10.8v pwm duty cycle 100% dc 12v cfm m 3 /min cfm m 3 /min pa inch h 2 o pa inch h 2 o 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 1,400 5.0 5.5 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 1,400 5.0 5.5 pwm duty cycle 100% 50% 0% 13.2v 12v 10.8v 60 cra type y 60 60 56 mm
pwm input signal example example of connection schematic speci?cations for pulse sensors output circuit : open collector t 1 ? 4 1/4 t 0 t 1 ? 4 1/4 t 0 1 60/4n sec n 1 fan speed min -1 one revolution in case of steady running output waveform need pull-up resistor inside of dc fan sensor output sensor pull-up resistor pull-up voltage input signal waveform t 100 t1 t 1 v ih =4.75v to 5.25v v il =0v to 0.4v pwm duty cycle % = pwm frequency 25 khz = source current : 5ma max. at control voltage 0v sink current : 5ma max. at control voltage 5.25v control terminal voltage : 5.25v max. (open circuit) when the control lead wire is open, the fan speed is the same as the one at a pwm duty cycle of 100%. either ttl input, open collector or open drain can be used for pwm control inpu t signal. pwm input signal dc fan input voltage control inside of dc fan isource isink v ce 1 13.8v max. ic 1 10ma max. | v ol 1 v ce sat 1 1.0v max. t t 1 v il t 0 t 1 0v v ol v oh t 2 t 3 t 4 v ih ic v ce pwm duty - speed characteristics example air flow - static pressure characteristics pwm duty cycle % speed min -1 voltage dc12v pwm frequency 25khz pwm duty cycle % speed min -1 pwm duty cycle % speed min -1 voltage dc12v pwm frequency 25khz voltage dc12v pwm frequency 25khz 9CRA0612P6K001 9cra0612p6g001 9cra0612p6j001 11,400 min -1 13,500 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 14,500 min -1 16,800 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 inlet side outlet side inlet side outlet side inlet side outlet side 15,800 min -1 100 0 0 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 20,000 18,300 min -1 ~ pwm duty cycle ~ operating voltage range static pressure air ?ow static pressure static pressure static pressure air ?ow static pressure air ?ow static pressure air ?ow air ?ow air ?ow pwm duty cycle 100 ? pwm duty cycle 100 ? pwm duty cycle 100 ? dc 12v dc12v pa inch h 2 o 9cra0612p6j001 pa inch h 2 o 9cra0612p6j001 cfm m 3 /min cfm m 3 /min pa inch h 2 o 9cra0612p6g001 pa inch h 2 o 9cra0612p6g001 cfm m 3 /min cfm m 3 /min 9CRA0612P6K001 9CRA0612P6K001 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 pwm duty cycle 100% 50% 0% 50% 0% 13.2v 12v 10.8v 13.2v 12v 10.8v pwm duty cycle 100% dc 12v cfm m 3 /min cfm m 3 /min pa inch h 2 o pa inch h 2 o 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 1,400 5.0 5.5 2.5 600 200 400 1. 0 0.5 1. 5 0 1. 5 0 0.5 1. 0 2.0 0 10 20 30 50 60 70 80 800 2.5 3.0 1,000 3.5 4.0 1,200 4.5 2.0 40 1,400 5.0 5.5 pwm duty cycle 100% 50% 0% 13.2v 12v 10.8v 60 cra type y 60 60 56 mm
60mm 60 60 56 mm inlet side , outlet side features counter rotating fan 60 counter rotating fan 60mm common speci?cations dimensions (unit : mm) reference dimension of mounting holes and vent opening (unit : mm) cra type | m 3 /min | cfm | pa | inchh 2 o | db(a) |? | h model no. rated voltage | v operating voltage range |v rated current | a rated input | w max. air flow max. static pressure spl operating temperature expected life note1) note2) pwm duty cycle |% note1 : pwm frequency : 25khz note2 : expected life at 40? ambient is just reference value. 12 10.8 to 13.2 20 to 70 40,000/60 ? (70,000/40 ? ) 30,000/60 ? 100 0 100 0 100 0 rated speed | min -1 i n l e t o u t l e t 3.10 0.17 2.30 0.15 1.30 0.10 9CRA0612P6K001 9cra0612p6j001 9cra0612p6g001 37.2 2.0 27.6 1.8 15.6 1.2 18,300 15,800 3,800 3,300 16,800 14,500 3,800 3,300 13,500 11,400 3,000 2,500 2 . 2 8 0 . 4 7 2 . 1 0 0 . 4 7 1 . 6 5 0 . 3 6 8 0 . 5 1 6 . 6 7 4 . 2 1 6 . 6 5 8 . 3 1 2 . 7 1 , 1 3 0 4 9 9 5 0 4 9 6 2 0 3 1 4 . 5 4 0 . 2 0 3 . 8 2 0 . 2 0 2 . 4 9 0 . 1 2 73 35 70 35 65 29 3-33-1, minami-otsuka, toshima-ku, tokyo, 170-8451, japan tel: +81 3 5927 1020 http://www.sanyodenki.com the names of companies and/or their products speci?ed in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. ?san ace? is a trademark of sanyo denki co.,ltd. speci?cations are subject to change without notice. 59 29.7 500.3 59 29.7 500.3 4-?4.5 speci?cations ? material kkkkkkkkkkkkkkkkkkkkkkkkkk ? expected life kkkkkkkkkkkkkkkkkkkkk ? motor protection system kkkkkkkkkk ? dielectric strength kkkkkkkkkkkkkkkk ? sound pressure level (spl) kkkkkkkk ? operating temperature kkkkkkkkkkkk ? storage temperature kkkkkkkkkkkkkk ? lead wire kkkkkkkkkkkkkkkkkkkkkkkk ? mass kkkkkkkkkkkkkkkkkkkkkkkkkkkkk frame, impeller : plastics (flammability: ul94v-0) varies for each model (l10: survival rate: 90% at 60?, rated voltage, and continuously run in a free air state) current blocking function and reverse polarity protection 50/60 hz, 500vac, 1 minute (between lead conductor and frame) expressed as the value at 1m from air inlet side varies for each model (non-condensing) 30 ? to 70 ? (non-condensing) i n l e t : redy ? blackysensor: yellow control: brown o u t l e t : orangey ? grayysensor: purple control: white approx. 200g ? the products shown in the catalog are subject to japanese export control law. diversion contrary to the law of exporting country is prohibited. ? to protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. notice catalog no. c1023b001 ?13.9 high air flow and high static pressure even with a thickness 20 mm less, the maximum air flow of this fan is approximately 1.1 times and its maximum static pressure is approximately 1.1 times greater than that of our conventional counter rotating fan. * this contributes to space optimization in devices. * : specification of model no. 9CRA0612P6K001. our conventional counter rotating fan is 60 x 60 x 76 mm ? san ace 60 ? cra type, model no. 9cra0612p0g001. air flow direction rotating direction rotating direction l e a d w i r e mounting hole a wg26 ul1430 inlet side outlet side 62.7 62.7 mounting hole 56 ? 0.5 (4) (4) 4-?4.5 ? 0.3 +50 30 0 0 (1 0) 60 ? 0.5 50 ? 0.3 60 ? 0.5 50 ? 0.3 4-?4.5 ? 0.3
|